A teaching tape for ME-03, system-boundary energy ledger with cited energy-source cards
where the energy went
Teaching tape demonstrating boundary energy balances: body alone loses mass, radiation carries energy, and the combined isolated system conserves total mass and energy.
Open ME-03 with these settings
Where it starts
| Setting | Value |
|---|---|
| Emitted radiation energy L (emittedEnergy) | 1 |
| External energy input Ein (inputEnergy) | 0 |
What it changes, and what to expect
Set Emitted radiation energy L (emittedEnergy) to 2 changes what the run starts from
Step 3
combined-isolated-system-balance
Inside a combined isolated enclosure, radiation absorption leaves total system mass unchanged.
What the author recorded that a reader should see here. Quantity Expected Under system energy change 0 J modern-si-2019 system mass change 0 kg modern-si-2019
These are the values the tape's author recorded, not a result this page computed. Nothing here runs the instrument. Open ME-03 with these settings: the link opens it with them already in place. Compare what it gives you with what is recorded here. The settings travel in the link and the laboratory reads them as it loads, so without JavaScript it opens at its worked example instead.